FG Wilson Generator Servicing, Sales, Spares & Repairs
Diesel Fuelled Generator Sets powered by Perkins Diesel Engines. Please select a KVA Range for further information. For our 24-hour on call emergency service, you can contact us by dialling 4932 3200.
|
10 to 35 kVA FG Wilson Diesel Generator
Gensets typically used for power in offices, shops, clinics, and for domestic purposes.
- Perkins 400 Series, 3 & 4 cylinder engines are used in this genset range
- Alternators are supplied by Leroy Somer – Industry Leader
- Robust, highly resistant construction
- Water-cooled, naturally aspirated
- Close circuit breathing
- Engine mounted battery-charging alternator
- Battery rack and cables installed on skid
- Engine lubrication oil
- Set-mounted exhaust system
- Plastic fuel tank with 8hr running capacity
FG Wilson's range of small generator sets is ideal for emergency back-up power in small offices, shops and domestic properties.
|
|
24 to 165 kVA FG Wilson Diesel Generator
These gensets are typically used for power in offices, shops, clinics, and for domestic purposes.
- Perkins 1100A Series 3 & 4 cylinder engines and 1006 Series 6 cylinder engines are used in the Non-emissions compliant generating set range
- Perkins 1100C Series 3 & 4 & 6 cylinder engines are used in the EU Stage II emissions compliant generating set range
- Minimum of 50% antifreeze as standard (protection up to -36ºC)
- Electronic governor as standard on P135 to P165E & P135P2 to P165E2
FG Wilson's range of generator sets from 24 - 165kVA are typically used for power in markets sectors including:
- Industry
- Telecommunications
- Healthcare
- Oil & Gas Rental market.
|
|
160 to 275 kVA FG Wilson Diesel Generator
Gensets for workshops, offices, telecommunications, schools, retail and financial sectors, and the rental market.
- Perkins 1300 Series & Scania DS1197A Series, 6 cylinder engines are both used for this generating range
- EU Stage II emissions compliant
- Alternators are supplied by Leroy Somer – Industry leader
- Service access enhancements
- Engine-Mounted battery-charging alternator
- Electronic governor as standard
- Heavy duty industrial silencer (supplied loose)
- Robotically welded, heavy duty, steel basetank with lifting points
- At least 8 hours of continuous operation on a single tank of fuel
- Minimum of 50% Anti-freeze (protection up to -36ºC) as standard
- Water-cooled
This genset range is ideal for use in sectors including:
- Industry
- Telecommunications
- Education
- Retail
- Financial sectors
- Rental Market
|
|
300 to 750 kVA FG Wilson Diesel Generator
Gensets typically for factories, office buildings, telecomms, hospitals, airports and the rental market.
- Perkins 2800 Series & Scania DC1254 Series, 6 cylinder engines are both used for this genset range
- Scania DSC11, DS11 & DC12 Series engines used for Brazil manufactured sets
- Alternators supplied by Leroy Somer - Industry leader
- Heavy duty industrial silencer (supplied loose)
- Drip catchment area in basetank for environmental protection
- Air outlet by vertical discharge
- Oil & radiator drains piped to baseframe
- Engine mounted battery-charging alternator
- Engine mounted fuel/water separator
- Easily extendable exhaust outlet pipe
- Robust, fully welded construction
- 50% Anti freeze (protection to -36ºC)
This FG Wilson range of generator sets is typically used for:
- Factories
- Telecommunications
- Hospitals
- Rental Market
- Other sectors include airports, office buildings and Gas Industries
|
|
|
730 to 900 kVA FG Wilson Diesel Generator
Gensets typically for factories, office buildings, telecomms, hospitals, airports and the rental market.
- Perkins 4000 Series 6 cylinder engines used in this genset range
- Alternators supplied by Leroy Somer - Industry leader
- Electronic governor as standard
- 33% Anti-freeze (protection up to –20ºC) as standard
- Heavy duty industrial silencer (supplied loose)
- Single point lift
- Fuel cooler
- Low oil pressure switch/sender
- Engine mounted battery-charging alternator
- Engine mounted fuel/water separator
- Easily extendable exhaust outlet pipe
- Robust, fully welded construction
This FG Wilson range of generator sets is typically used for:
- Factories
- Telecommunications
- Hospitals
- Rental Market
Other sectors include airports, office buildings and Oil and Gas Industries
|
|
|
910 to 2,200 kVA FG Wilson Diesel Generator
Gensets used for large factories, mini power stations, airports, hospitals and the financial sector.
- Perkins 4000 Series 8, 12 & 16 cylinder engine range
- AREP Alternators supplied by Leroy Somer – Industry leader
- Electronic governor as standard
- Industrial capacity heavy duty silencer (supplied loose)
- Engine mounted battery-charging alternator
- Piston cooled by advanced gallery jet cooling system
- Robust, welded construction
- Engine mounted fuel/water separator
- Charge Air Cooled
(P1250P3, P1375E3 & P1350P1 & P1500E1 Water Cooled Only)
- Disc Coupling
- Lifting Points
- Fuel Cooler
These gensets, in our highest kVA range are used for:
- Large factories
- Mini power stations
- Airports
- Hospitals
- Financial sector.
|
|
|
|